RE: [FW1] Why choose Nokia? Here's why.




Just out of curiosity, were those machines tuned at all? The 25k limit on NT matches the default concurrent connections in FW1.


Mark Ingles

At 09:02 PM 9/21/00 , Tim Cullen wrote:
These numbers are a little off. The numbers we were able to produce with SmartBits product was 25,000 concurrent connections for NT, 35,000 concurrent for Solaris UE2, and 80,000 concurrent for the Nokia IP650. These are actual numbers as tested. Your mileage may vary.
-----Original Message-----
From: Richard Peirce [mailto:[email protected]]
Sent: Thursday, September 21, 2000 7:49 PM
To: 'Ed Davidson'; [email protected]
Subject: RE: [FW1] Why choose Nokia? Here's why.

Nokia is 100,000
Solaris is 30,000
NT is 8,000
-----Original Message-----
From: Ed Davidson [mailto:[email protected]]
Sent: Thursday, September 21, 2000 4:51 PM
To: [email protected]
Subject: RE: [FW1] Why choose Nokia? Here's why.

How many connections is that in actual numbers?

Thanks.
-----Original Message-----
From: [email protected] [mailto:[email protected]]On Behalf Of Richard Peirce
Sent: Thursday, September 21, 2000 3:14 PM
To: [email protected]
Subject: RE: [FW1] Why choose Nokia? Here's why.


The Nokia appliance will also allow 10x the number of connections that NT and 3x the connections a Solaris box will