Re: [FW-1] Firewall and RH 7.0



Hola Aeon,

Thursday, October 11, 2001, 12:55:34 PM, escribió:

AH> I'm trying to get Checkpoint installed on RH 7.0.  It's being a pain.
AH> Basic RH installation.  In fact, off the 4.1, SP2 Checkpoint CD, rpm -ih
AH> ***.rpm works great.  It installs Base version of checkpoint no problem,
AH> i think version 414**...not sure of the rest.  Anyway, I get it all
AH> setup, licensed, users, gui-clients, etc....reboot...no prob.  I goto
AH> upgrade to SP2 or SP3, it doesn't like that.  Says it need CPfw-1
AH> installed first.  I run  rpm -u ...rpm  --nodeps (which usually works in
AH> the past) and it installs....doesn't seem to be giving me grief.  I goto
AH> reboot...KERNEL PANIC...

AH> I know somebody out that has successuflly installed this on 7.0.  I've
AH> done 6.2 way too many times and I'd be happy to stick with it, but RH
AH> 6.2 doesn't like my AMD Athlon CPU.

AH> Any help would be appreciated.

AH> Thanks,

AH> Aeon Hale
AH> Security Engineer
AH> CCSA,CCSE,CCSI
AH> Accenture


AH> ================================================================================
AH>      To unsubscribe from this mailing list, please see the instructions at
AH>                http://www.checkpoint.com/services/mailing.html
AH> ================================================================================

These were my steps for red hat 7.0 & FW-1:
      - Install RH 7.0
      - Interfaces , services, network ...
      - RPMs installation:
             ·  sharutils-4.2.1-7.i386.rpm
             ·  compat-libstdc++-6.2-2.9.0.9.i386.rpm
             ·  compat-glibc-6.2-2.1.3.2.i386.rpm
      - FW-1 & SP2 -->· CPfw1-41-vpn+des.i386.rpm
      - SP4 --> · CPfw1-41.4-SP4.i386.rpm

That worked for me, not in this order , as I was required to install
those rpm when trying to install FW-1.

Good Luck


--

  Eduardo Eirós Valle                            mailto:[email protected]

  Nextel S.A. Ingeniería Telemática

  Tlf: +34 944035555  Fax: +34 944035550

  Parque Tecnológico Edif. 207, Bloque B, 1º

  48170- Zamudio (Bizkaia)

================================================================================
     To unsubscribe from this mailing list, please see the instructions at
               http://www.checkpoint.com/services/mailing.html
================================================================================



 
----------------------------------

ABOUT SERVICES PRODUCTS TRAINING CONTACT US SEARCH SUPPORT SITE MAP LEGAL
   All contents © 2004 Network Presence, LLC. All rights reserved.